Our services

Paints for Chambers and Bells
The Comanex paints are suitable for painting of internal / external of Diving Bell and Chambers. These paints have been developped for the hyperbaric use. Various paints are available: Epoxy paint for first coat and corrosion...
More details
Bell / Chamber Hangable Light
• Suitable for: - DDC Bunk box featuring two 24 V bulbs: - 4 W for main light - 2.5 W for secondary light - SDC emergency light featuring 12 V / 4 W bulbs and power supplied by the emergency battery pack • Water and impact resistant...
More details
Pressure Vessel Internal Lighting
This system designed by COMEX INDUSTRIES wears a DNV approval provided that the bulbs and the bulb holders are of a specific type.
More details
Bell Umbilical Junction Boxes
Umbilical dry Junction box.The stainless steel junction box features a transformer, insulation control device and connectors. Several designs are available.
More details
Underwater Flood Light
- Rated 600 msw (60 bar) - Pressure tested at 90 bar - LED type - Lightning : 10,000 Lumen - Lightning angle : 135° - Casing and bolts : Cupro aluminium & Stainless steel - Viewport : PMMA - Including Stainless steel supporting...
More details
Manual O2 Add Manifold and Intelock
The O2 add manifold controls the O2 injection in the diving bell or the HRC by means of one buffer tank. The interlock between the two valves prevents the O2 storage gas bottle to be in direct communication with the hyperbaric vessel when the...
More details
DIV 38 Alarm
COMEX diving bells feature a DIV 38 shuttle valve fitted on the breathing panel.In case of lack of breathing gas coming from the umbilical, the shuttle valve automatically by-passes the umbilical and puts in use the gas coming from the onboard gas...
More details
Manually operated - OPEN
COMEX standard guide line release system is made of blocks welded on the bell cage featuring bronze bushings.Two types of release system are available: Manually operated Hydraulically operated from inside the bell.  The hydraulic...
More details
Bell Ballast Release System Bushings
The ballast release system is designed to comply with DNV rules according to buoyant ascent of the bell. The ballast is hold by 2 short flat bars and 2 long chains.Each bar and chain is connected to the bell by a release system that can be...
More details
Heating Elements
• Designed for sea water heating• Material:- Inconel heating element- Stainless steel flange- Teflon spacer• Sealing: IP 679Other specification on request
More details
DIV 51 Flow Fuse Repair Kit
This Flow limitor closes automatically in order to avoid an unwanted discharge of the pressure in a hyperbaric vessel due to a pipe breakage It is not anymore manufactured Only seal kits are available. Also old flow fuses (if not in too bad...
More details
EV100 Oxygen Solenoid Valve
This valve is designed to be fitted in an oxygen automatic addition system• Brass & steel body• O2 max. pressure: 100 bar• Seat: PCTFE• Cleanliness: O2 usePower supply: 24VDC
More details
DIV 38 Shuttle Valve
The Shuttle valve is designed to supply the breathing mixture to the divers in normal and emergency case.In Normal use, the user outlet is supplied by the umbilical.In case of accidental cut off of the supply coming from the surface, the shuttle...
More details
D110 Pressure Reducer
The D110 Pressure Reducer is specially designed for Bell O2 add. • Watertight • Brass body • Back-up pressure: 250 bar • Outlet pressure: 2 to 5 bar • Seat: PCTFE • Inlet/outlet: 1/4” BSP •...
More details
D108 Pressure reducer
D108 Pressure Regulator works like the D106 Pressure Regulator, but the diaphragm is replaced by a piston to allow outlet pressure up to 50 bar• Brass body• Back-up pressure: 250 bar• Outlet pressure: 2 to 50 bar• Seat:...
More details
D107 Pressure Reducer
The D107 Pressure Reducer is specially designed for Bell analysis line. • Watertight • Brass body • Back-up pressure: 250 bar • Oulet pressure: 0.1 to 1.5 bar • Seat: PCTFE • Inlet/outlet: 1/4” BSP •...
More details
D106 Pressure Reducer
The D106 Pressure Reducer is specially designed for DDC analysis line. • Brass body • Back-up pressure: 250 bar • Oulet pressure: 0.1 to 1.5 bar • Seat: PCTFE • Inlet/outlet: 1/4” BSP • Cleanliness: O2 use
More details
F1509 Filter
The 1509/L Filter is used in order to protect the downstream equipment against dirt and foreign particles. It is mainly used assembled with the D79/L regulator thanks to a special connector 3/8"BSP male fitted: This is the F1509/L Inlet: 3/8"BSP...
More details
D79/L Pressure Reducer
• Brass body• Back-up pressure: 250 bar• Outlet pressure: 7 to 52 bar• Threaded hole: 3/8’’ BSP• Seat: brass and PCTFE• Cleanliness: O2 use
More details
F1526 Filter
The F1526 Filter is used exclusively in INTEGRABLOC circuits in order to protect the downstream equipment against dirt and foreign particles. It is mainly used assembled with the D104 regulator. The filter cartridge can be replaced without...
More details
D104 Pressure Reducer (D79/L Cx Integrabloc)
• Brass body• Back-up pressure: 250 bar• Outlet pressure: 7 to 52 bar• Seat: brass and PCTFE• Cleanliness: O2 use
More details
RO 52 Drain Valve
• Brass body• Working pressure: 250 bar• Seat: PCTFE• Cleanliness: O2 cleaned
More details
Integrabloc System
Principle:These modular elements include the main components of a gas panel: filters, regulators, dump valve, safety valves, non-return valves, valves, solenoid valves ... also input and output blocks, connection blocks that can receive pressure...
More details
RO 48 Integrabloc HP Valve
• Brass body• Working pressure: 250 bar• Seat: PCTFE or copper for O2• Cleanliness: O2 cleaned
More details
Gas Storage Valves
Onboard bottle valves, Tube and quad valves are available• Brass body• Working pressure: 200 bar
More details